Loading...
Configure a DiGiCo Pad external-control device on the console, then configure the DiGiCo module with the matching network ports. The steps below apply to SD and Quantum consoles; the required Commands Allowed file depends on the console family.
The examples use UDP ports 7000 and 7001 for OSC communication. These are used so as to not conflict with Companion's default Web UI port 8000.
On the console, open System → External Control and set Enable External Control to Yes.
Under External Devices:
Companion).7000 and Rcv to 7001, then enable the device.Use DiGiCo Pad, rather than Other OSC, to access DiGiCo's remote-control command set.
In the Commands Allowed section at the bottom of External Control, select Load and choose the file for your console family. If an incorrect command set is already loaded, select Clear All first.
| Console family | Commands Allowed file |
|---|---|
| SD8, SD9, SD11, SD12, SD12-96 | iPadv2sd8-9-11-12 |
| Quantum | ipad_q3 (the iPad v2 Quantum command file) |
After loading, confirm the command list is populated and No commands are enabled is no longer shown.
In the module, use the console's Local IP Address from the External Control window as the destination, and set the ports as follows:
| Module setting | Value |
|---|---|
| Receive Port | 7000 |
| Transmit Port | 7001 |
| Mixer IP Address | Console Local IP Address |
The port numbers are from the console's perspective: its Rcv 7001 receives Companion commands, and its Send 7000 sends console feedback to the Companion computer.
The module can relay OSC between the console and a DiGiCo iPad app while it remains connected to Companion.
7002 and iPad Transmit Port 7003. The receive port must differ from the module's Receive Port (7000 by default).Port direction is from the module's perspective: OSC from the iPad arrives at Companion on 7002, is forwarded to the console using the module's normal transmit settings, and console OSC replies are sent to the iPad at its configured IP and port 7003. If you change either iPad port in Companion, use the matching port in the app. Keep these ports available on the network and firewall.
Choose the relevant DiGiCo action and select the channel, output, snapshot, macro, or other item. Where a selector supports multiple choices, use it to target more than one item; All targets every available choice. Numeric values use the units shown in the field label. Relative applies a change to the current value, and Cross-fade ramps supported numeric values over the selected duration.
On/off actions provide Off, On, and Toggle where the console command supports them. Toggle reads the current console value before sending the opposite state.
Value feedbacks report the selected console value for expressions and Companion logic. Their results can also drive text or internal actions. For button coloring, use the matching (On) boolean feedback for supported on/off parameters; set its feedback style in Companion to choose the active color. [Macros] OSC button state is a boolean feedback for macro buttons.
When upgrading the legacy Change button color for macro state feedback, its Use Console Macro Name option is not carried over. The replacement [Macros] OSC Macro State feedback controls colors only; set the button text separately if you want it to show the macro's name.
The module provides count variables for channel and entity families, plus Filename for the current console session filename. Counts update as the module discovers the console's available channels and records. Use the variable picker to see the exact variable names available for this connection.