Loading...
ET50-3D · ET250R2-3D · ET250-3D
Control Outline ET turntables (ET50-3D, ET250R2-3D and the legacy ET250-3D) from Bitfocus Companion: STOP, step, nudge, go to an angle and set zero, with live position, motion state and turntable identity.
The module sends only movement commands, set zero and reads. It never changes any setting of the turntable: speed, memory writes, network settings and firmware update are not implemented. Set zero redefines the position reference only when you ask for it.
Safety: the network STOP is not an emergency stop. Keep the turntable's own safety measures in place.
6667. Position telemetry is read from the next port (6668 by default).Add one connection per turntable, and only one: see One client per turntable. ET Controller does not need to be running.
When the fixed local port opens, including after a restart, position polling waits 2 s so replies from the previous connection cannot become telemetry or confirm a STOP during that window. The connection stays Connecting until fresh telemetry and identity are available. STOP can still be sent as soon as the socket is ready. The protocol has no request IDs: replies delayed beyond the guard can still be ambiguous. With an automatic port, used when the fixed one is taken, polling starts at once.
0.5° from 0.5° to 359.5°. Other values, such as 0.3°, are refused.0.5°, like MAN in ET Controller.0.5° from 0° to 360°, where 360° is 0°), forward, backward or along the shortest path (an exact half turn goes forward). Nothing is sent when the turntable is already there.0° (RESET TO 0 in ET Controller). Only while the turntable is stopped; a position read afterwards must show 0°. The turntable does not move. The previous zero reference is lost. Check the zero after the turntable has been switched off and on.Angles accept fixed values, variables and expressions. Step and go-to angles must be multiples of 0.5°, the granularity of the movement: other values, such as 0.3°, are refused and the log tells why.
How movements are handled:
motion variable to know when the turntable has stopped (see Sequences).The motion variable switches to forward or backward as soon as a movement is confirmed and back to stopped when the turntable stops, even for a movement shorter than one position reading. A trigger on the change of motion, with the condition motion = stopped, can start the next step of a sequence, for example a measurement in another program.
The module uses one local UDP port for the whole connection, for both the command and the position port, to take as few of the turntable's connections as possible. The port is the same at every restart of Companion or of the connection: 20000 plus the last two octets of the turntable address (third × 256 + fourth), modulo 10000; 192.168.1.120 gets 20376. If that port is taken, for example by a second connection to the same turntable, by a connection to another turntable whose address gives the same port, or by another application, the log says so and an automatic port is used. Requests leave one at a time: each waits for the reply to the previous one, or for its timeout. Any two datagrams to the turntable are at least 10 ms apart, and a command leaves at least 10 ms after the end of the previous movement. STOP is exempt from all these rules and always leaves at once: a command still waiting for its turn is then dropped, never sent.
0.5°). The distance is circular: 359.9° is 0.1° away from 0°.Without valid telemetry every feedback is false.
| Variable | Content |
|---|---|
position | Position in degrees as a number; empty without telemetry |
position_text | Position for buttons, e.g. 123.4°; — without telemetry |
motion | stopped, forward, backward or unknown |
model | ET50-3D, ET250R2-3D, ET250-3D, or empty when not known |
name | Name stored in the turntable |
firmware | Firmware version of the turntable |
Forward and backward are the directions of the ▶ and ◀ buttons in ET Controller.
0°); GO 90°, 180° and 270° along the shortest path; SET 0, which acts only after the button is held for 2 s. They turn green when the turntable is stopped on their angle.Buttons turn amber while the turntable moves and grey without telemetry.
After dropping a GO preset, use the button's Local Variables panel to change Target angle (°) (0–360, in multiples of 0.5°) and Direction (forward, backward or shortest). The action, button text and at-angle feedback share that target; the action and text share the direction. For ZERO, change Direction (forward, backward or shortest); its target stays at 0°. Keep the generated expressions in the action, feedback and button text so these values stay linked. These presets require Companion 4.3 or later.
STEP and MAN use fixed labels: if you edit their action options, also update their button text.
The turntable supports a limited number of network clients. With a second client querying it, especially during a movement, a turntable can stop answering anything, STOP included, until it is switched off and on. Therefore:
If the turntable stops answering, stop it from the front panel if needed, then power-cycle it.
The front panel stays available. Movements started there appear in Companion within about a second, and Companion refuses new movements while they run. There is no arbitration between operators: use one of them at a time.
| Model | Status |
|---|---|
| ET250R2-3D | Tested with firmware 1.3.1 |
| ET50-3D | Same firmware as the ET250R2-3D, with a faster motor; recognised automatically |
| ET250-3D (v1, legacy) | Tested with firmware 1.03; recognised automatically by its MAC. It may miss a position reply now and then: the module retries automatically, without a warning |
The model is detected when the connection starts: there is nothing to choose in the configuration.
Outline