Control and monitor the Sonifex AVN-M8R.
Input controls use Ember+. Metering, input names, GPI mute and status LEDs use WebSocket. Device uptime, core temperature and PoE presence are received over WebSocket and polled over HTTP every 30 seconds.
Input settings (Mic/Line mode, phantom power, preamp gain, full-scale level, high-pass filter, signal-presence timeout and threshold, and mute) are controlled using Ember+.
Select Input 1 to Input 8 for each input action.
In expression mode, options take the values their labels show: inputs 1 to 8, full-scale levels 15, 18, 20, 22 or 24, input mode mic, line or toggle, and the other state options on, off or toggle.
| Action | Available settings |
|---|---|
| Set Input Mode | Mic, Line or Toggle |
| Set Phantom Power | Off, On or Toggle |
| Set Preamp Gain | 16 to 76 dB in 3 dB steps |
| Adjust Preamp Gain | Increase or decrease by 3, 6, 12, 15 or 30 dB, limited to 16 to 76 dB |
| Set Full Scale Level | +15, +18, +20, +22 or +24 dBu |
| Set High-Pass Filter State | Off, On or Toggle |
| Set High-Pass Filter Frequency | 40 to 3000 Hz in 5 Hz steps |
| Set Signal-Presence Timeout | 0 to 300 seconds |
| Set Signal-Presence Threshold | -70 to 0 dBFS |
| Set Input Mute | Unmuted, Muted or Toggle (software mute) |
| Set Status LEDs | Disabled, Enabled or Toggle |
Set Status LEDs applies to the whole device and uses WebSocket. Toggle actions and relative gain adjustments require the current setting to have been received from the device.
0 or 1, input mode uses 0 for Mic and 1 for Line, full-scale level uses its level in dBu (18, +18 or +18 dBu). The text the input's variable shows also matches, for example Line, and Learn fills in that text.<, = or > against a level in dBFS.Input levels are reported as a segment count from 0 to 21, rather than a continuous dBFS measurement. Zero means below -52 dBFS, segment 21 represents the top band starting at -0.1 dBFS. Only the levels listed in Input Meter Level can be distinguished. Its = comparison matches a meter band, rather than an exact measured dBFS value. In expression mode, enter the level in dBFS (e.g. -18). A level between two listed levels is rounded down, so -20 behaves like -21 dBFS, and anything below -52 dBFS counts as silence.
For a custom gauge, use input1_meter (or the corresponding input variable) with a minimum of 0 and a maximum of 21.
Set Input Mute Action changes only the software mute. An input remains muted while either software mute or GPI mute is active, so clearing software mute cannot override an active GPI mute.
Use the Input Mute feedback's Software or GPI source to show the combined state. The mute preset toggles software mute and shows red when muted, with amber taking priority while GPI mute is active.
The module provides the following variables for each input. Replace input1 with input2 through input8 as required.
| Variables | Contents |
|---|---|
input1_dante_label, input1_friendly_name | Input names reported by the device |
input1_mode | Mic or Line |
input1_phantom_power | Phantom power state |
input1_preamp_gain | Preamp gain in dB |
input1_full_scale_level | Full-scale level, including dBu units |
input1_hpf_enabled, input1_hpf_frequency | High-pass filter state and frequency in Hz |
input1_signal_presence_timeout, input1_signal_presence_threshold | Signal-presence settings in seconds and dBFS |
input1_mute, input1_gpi_mute, input1_mute_active | Software, GPI and combined mute states |
input1_meter | Meter segment count, 0 to 21 |
Device variables are status_leds_enabled (0 or 1), device_uptime, device_temperature (degrees Celsius), primary_poe_present and secondary_poe_present (Present or Not Present).
The module automatically retries dropped WebSocket or Ember+ connections. If meters update but input actions fail, check access to Ember+ on port 9000 and review the Companion log for parameter discovery or connection errors. If temperature, uptime or PoE information is missing, check access to the device's HTTP and WebSocket interfaces.