Bitfocus AS
logo
logo
Bitfocus AS
logo
logo
Sign upSign in

Loading...

Bitfocus

Subscribe to our newsletter

The latest news, articles, and resources, sent to your inbox.

FacebookInstagramGitHubYouTubeLinkedIn

Products

  • Buttons
  • Companion

Integrations

  • Supported Devices
  • Developer Community
  • Connection Development

Support

  • Support Overview
  • Documentation
  • Video Tutorials
  • Community Forum

Sales

  • Resellers & Integrators
  • Buttons Pricing

Updates

  • Case Studies
  • Events & Trade Shows
  • Press Releases
  • Product Updates
  • Webinars

Legal

  • Legal Overview
  • Privacy Policy
  • Buttons EULA
  • Terms & Cookie Policy

Company

  • About us
  • Press kit
  • Careers

© 2026 Bitfocus AS. All rights reserved.

Install USB Relay on Windows
Docs for
Overview
Getting started
What is Bitfocus Buttons?
Install Buttons and get started
Manage your Buttons license
Activate Buttons offline
Find your way around Buttons
Create your first backup
Add an ATEM connection
Choose a control method
Choose an installation path
Install Buttons on Debian or Ubuntu
Understand HA clustering
Kubernetes HA
Update or remove Buttons
Positions
Understand positions
Create a position
Add controls and sections to a position
Create your first button
Use a connection's presets
Build more capable button actions
Add more feedback to a button
Organize controls in a section
Shift Section
Organize controls with a Folder Section
Add a Popover Section
Build and reuse a Shared Section
Build a Router Section
Understand Custom Routers
Custom Router panel
Surfaces
Surface compatibility
Add and attach a surface
Device orientation
Connections
Update a connection's module safely
Monitor and troubleshoot a connection
Router integrations
VideoHub and AJA KUMO
Utah Scientific BPS
Generic SW-P-08
Nevion VideoIPath
Arkona BLADE//runner
Routing
Physical routing
Configure ports and labels
Take a physical route
Understand route status
Topology graph
Routing Presets
Get started with virtual routing
Configure Nested Shapes
Reverse routing
Tielines
Routing Projects
Routing settings
Troubleshoot a route
Tally
Understand the Tally system
Send ATEM tally and labels to a UMD
Interpret Active Tally state
TSL/UMD connections
Diagnose tally problems
NMOS
Understand NMOS in Buttons
Connect Buttons to an NMOS Registry
Built-in Registry Server
Configure NMOS connections
Discover and adopt
Browse the NMOS inventory
Manage NMOS multicast addresses
Diagnose NMOS problems
Understand Cuelists
Build a Cuelist
Read and advance a running Cuelist
Control a Cuelist from a Position
Workflows
Understand workflows
Build your first workflow
Reuse a group of workflow nodes safely
Troubleshoot a workflow
Recipes
Sequence a timed automation
Call an HTTP endpoint from a workflow
REST endpoint
Use variables
Understand variable scope
Understand nested variables
Update expressions for v1.8
Plan and use Tags
Access
Create and manage users
Create roles and assign permissions
Grant access to specific resources
Show different controls by role
Sessions
Set up PIN and NFC sign-in
SSO
Get started with SSO
Connect a generic OIDC provider
Connect LDAP or Active Directory
Map identity claims to roles
Secure a Buttons deployment
Integrations
External control
Connect to Bitfocus Listener
USB Relay
Install USB Relay on Windows
Install USB Relay on macOS
Install USB Relay on Linux
Install USB Relay on a Raspberry Pi
Get started with the Control API
Secure and monitor the Control API
Control API reference
API reference
Administration
Enable and manage installable features
Services and health
Configure and monitor scheduled backups
Restore a backup and verify it
Export or import Buttons configuration
Store and rotate connection secrets
Replace the HTTPS certificate
HA backup and recovery
Settings
Collect support information
Reference
Glossary
Button Inspector reference
Network ports reference
Expressions
Internal actions reference
Routing Presets panel reference
Startup configuration reference
Workflow nodes
Connection workflow nodes
Workflow workflow nodes
Internal workflow nodes
Position workflow nodes
API workflow nodes
Utility workflow nodes

Loading...

Previous
← Connect to Bitfocus Listener
Next
Install USB Relay on macOS →
Contact support →
You are viewing documentation for Buttons 1.8.See the docs for Buttons 1.6
Buttons/Integrations/USB Relay/Install USB Relay on Windows

Install USB Relay on Windows

USB Relay lets a Stream Deck plugged into a Windows PC show up in Buttons as a network surface, even though it isn't physically attached to the machine running Buttons. Once running, Buttons discovers it and any Stream Deck attached to it, and you adopt them the same way as any other surface.

Before you begin#

  • The Windows PC has any Stream Deck hardware you want to relay plugged in.
  • Network connectivity between this PC and your Buttons installation.
  • A Buttons license above the free tier: adopting a USB Relay surface requires at least an Individual-tier license.

Install#

  1. Download the Windows installer and run it.
  2. Accept the prompts and the license agreement.
  3. Leave Install and start as a Windows service checked (this is the default) if you want USB Relay to always run in the background and start automatically. Uncheck it if you'd rather start it manually yourself.
  4. Select Install, then Close once it finishes.
The installer also adds a firewall rule for the relay's network port.

Run it#

If you installed it as a service, it's already running: no further action needed. If you left the service option unchecked, launch the application yourself (a shortcut is created for this); a command-line window opens and stays open while it runs. Closing that window, or pressing Ctrl+C inside it, stops the relay.
By default, USB Relay runs in server mode: it listens for a connection and announces itself on the network so Buttons can find it automatically. No further configuration is needed for this.

Discover and adopt it in Buttons#

Once running, open Buttons and follow the normal discovery flow: see Add and attach a surface. The relay itself appears in the discovered list labeled USB Relay; adopting it also makes any Stream Deck attached to that PC available to adopt, either from the relay's own settings or back in the main Surfaces list.

Manage the service#

  • Check or change startup behavior: open services.msc (press Win+R, type services.msc), find Bitfocus Buttons USB-Relay, and use its Properties to change the startup type or start/stop it manually.
  • Reinstall or remove just the service registration: the installed application also accepts service-management commands directly; running it with install-service, uninstall-service, start-service, stop-service, or status-service manages the Windows service without reinstalling the whole application. Reinstalling the service this way is safe to repeat; it replaces any existing registration rather than failing.
  • Fully remove USB Relay: use Windows' own Add or remove programs.

Connect outbound to a specific Buttons address#

If your network doesn't support automatic discovery, point the relay at your Buttons installation directly instead of waiting to be discovered. Add -buttonsAddress <ip>:<port> when running it manually, or bake the flag into the service registration by reinstalling the service with that flag included.

Note

There's no separate flag to change the relay's own listening port; it only changes via an environment variable (USB_RELAY2_PORT) if you genuinely need something other than the default.

If Buttons' certificate changes#

If you replace Buttons' own HTTPS certificate (see Replace the HTTPS certificate) while a relay is already connected outbound to it, the relay notices the certificate no longer matches what it trusted before and refuses to reconnect, to protect against a silently swapped server. If you changed the certificate intentionally, add -accept-cert-change once to have the relay trust and remember the new one.

If you get stuck#

What you see
What to try
The relay doesn't appear in Buttons' discovered surfaces.
Confirm it's actually running (check services.msc, or that its command-line window is still open), and that both machines are on a network that supports discovery.
The relay's command-line window shows an error about being unable to multicast.
The relay can't broadcast itself on the network, usually due to a Public network profile, VPN, or a corporate network that blocks discovery traffic. Skip discovery entirely by connecting it outbound: see Connect outbound to a specific Buttons address above.
You need it to connect outbound instead of waiting to be discovered.
Add -buttonsAddress <ip>:<port> when running manually, or reinstall the service with that flag included.
The relay refuses to reconnect after you replaced Buttons' HTTPS certificate.
This is expected protection against an unexpected certificate change: run it once with -accept-cert-change if the change was intentional.
You want to change which port the relay listens on.
Set the USB_RELAY2_PORT environment variable: there's no command-line flag for this.

Where to go next#

  • Add and attach a surface
  • Manage your Buttons license

Was this helpful?

Was this helpful?

0 of 0 users found this page helpful