Discover and adopt
Docs for
Overview
Getting started
What is Bitfocus Buttons?
Install Buttons and get started
Manage your Buttons license
Activate Buttons offline
Find your way around Buttons
Create your first backup
Add an ATEM connection
Choose a control method
Choose an installation path
Install Buttons on Debian or Ubuntu
Understand HA clustering
Kubernetes HA
Update or remove Buttons
Positions
Understand positions
Create a position
Add controls and sections to a position
Create your first button
Use a connection's presets
Build more capable button actions
Add more feedback to a button
Organize controls in a section
Shift Section
Organize controls with a Folder Section
Add a Popover Section
Build and reuse a Shared Section
Build a Router Section
Understand Custom Routers
Custom Router panel
Surfaces
Surface compatibility
Add and attach a surface
Device orientation
Connections
Update a connection's module safely
Monitor and troubleshoot a connection
Router integrations
VideoHub and AJA KUMO
Utah Scientific BPS
Generic SW-P-08
Nevion VideoIPath
Arkona BLADE//runner
Routing
Physical routing
Configure ports and labels
Take a physical route
Understand route status
Topology graph
Routing Presets
Get started with virtual routing
Configure Nested Shapes
Reverse routing
Tielines
Routing Projects
Routing settings
Troubleshoot a route
Tally
Understand the Tally system
Send ATEM tally and labels to a UMD
Interpret Active Tally state
TSL/UMD connections
Diagnose tally problems
NMOS
Understand NMOS in Buttons
Connect Buttons to an NMOS Registry
Built-in Registry Server
Configure NMOS connections
Discover and adopt
Browse the NMOS inventory
Manage NMOS multicast addresses
Diagnose NMOS problems
Understand Cuelists
Build a Cuelist
Read and advance a running Cuelist
Control a Cuelist from a Position
Workflows
Understand workflows
Build your first workflow
Reuse a group of workflow nodes safely
Troubleshoot a workflow
Recipes
Sequence a timed automation
Call an HTTP endpoint from a workflow
REST endpoint
Use variables
Understand variable scope
Understand nested variables
Update expressions for v1.8
Plan and use Tags
Access
Create and manage users
Create roles and assign permissions
Grant access to specific resources
Show different controls by role
Sessions
Set up PIN and NFC sign-in
SSO
Get started with SSO
Connect a generic OIDC provider
Connect LDAP or Active Directory
Map identity claims to roles
Secure a Buttons deployment
Integrations
External control
Connect to Bitfocus Listener
USB Relay
Install USB Relay on Windows
Install USB Relay on macOS
Install USB Relay on Linux
Install USB Relay on a Raspberry Pi
Get started with the Control API
Secure and monitor the Control API
Control API reference
API reference
Administration
Enable and manage installable features
Services and health
Configure and monitor scheduled backups
Restore a backup and verify it
Export or import Buttons configuration
Store and rotate connection secrets
Replace the HTTPS certificate
HA backup and recovery
Settings
Collect support information
Reference
Glossary
Button Inspector reference
Network ports reference
Expressions
Internal actions reference
Routing Presets panel reference
Startup configuration reference
Workflow nodes
Connection workflow nodes
Workflow workflow nodes
Internal workflow nodes
Position workflow nodes
API workflow nodes
Utility workflow nodes

Loading...

Previous
← Configure NMOS connections
Next
Browse the NMOS inventory →
Contact support →
You are viewing documentation for Buttons 1.8.See the docs for Buttons 1.6
Buttons/NMOS/Discover and adopt

Discover and adopt

NMOS discovery and adoption can help you bring senders and receivers into Buttons and start routing them within seconds. Select the nodes you want to control, adopt them as connections, and their routing resources become available alongside other sources and destinations.
This guide follows the shortest path: adopt peer-to-peer nodes discovered directly through mDNS, inspect their resources, and take a route.

Before you begin#

You need:
  • The NMOS feature enabled.
  • Access to create NMOS connections and execute routes.
  • NMOS peer-to-peer nodes visible through mDNS.
  • At least one sender and one compatible receiver. They can belong to the same node or different nodes.

Adopt discovered nodes#

  1. Open Connection → NMOS.
  2. Select Discovered nodes at the bottom of the connection list.
  3. Find the node that supplies the sender or receiver you want to use. The discovery list shows its type, label, UUID, address, when it was last seen, and how it was discovered.
  4. Select the node. Select both the sending and receiving nodes when they are separate.
  5. Select Adopt selected.
The discovery panel closes and the adopted node appears in the NMOS connection list. A newly adopted peer-to-peer node may briefly show Fetching Initial State while its NMOS resources are loaded.
If several records describe the same node, the discovery view combines them so you can adopt the node once.

Confirm the senders and receivers#

  1. Select the adopted node in the NMOS connection list.
  2. Open Ports and Bundles.
  3. Look under Sources for bundles available to route from the node.
  4. Look under Destinations for bundles available to route to the node.
For a simple example, identify a source such as Camera 1 and a destination such as Engineering Monitor. If the source and destination belong to separate nodes, inspect Ports and Bundles on each connection.
The resource counts and cards come from the adopted node's NMOS data. You do not need to create each sender and receiver as a routing port manually.

Take the first NMOS route#

Selecting Take changes the signal received by the chosen destination.
  1. Open Routing → Execute.
  2. Above Sources, use the NMOS node filter to select the adopted node that contains Camera 1.
  3. Above Destinations, use the same filter to select the adopted node that contains Engineering Monitor.
  4. Leave Bundles selected.
  5. Select Camera 1 under Sources.
  6. Select Engineering Monitor under Destinations.
  7. Review the staged route and select Take.
A successful request reports Routes executed successfully. The destination's active-source display updates from the state reported by the NMOS receiver.

Adopt a node from a Registry#

When the node is available through an adopted NMOS Registry connection:
  1. Open Connection → NMOS and select the Registry connection.
  2. Open All Nodes.
  3. Find the node and select Adopt.
The node changes to Adopted and appears under Adopted Nodes and in the NMOS connection list. Open the node's Ports and Bundles to inspect its routing resources, then follow the same routing steps above.

Add a node manually#

Use manual setup when a peer-to-peer node cannot be discovered through mDNS, such as a node on another subnet.
  1. Open Connection → NMOS.
  2. Select Manual Add.
  3. Select Node.
  4. Enter a Label and one or more Node endpoints.
  5. Leave IS-04 set to automatic selection unless the node requires a specific supported version.
  6. Select Create.
Endpoints are tried in the order shown. After the connection loads its NMOS data, open Ports and Bundles to inspect the generated resources.

If you get stuck#

What you see
What to try
The peer-to-peer discovery list is empty.
Confirm that mDNS discovery is enabled under Settings → NMOS and that the node is announcing on a reachable network. DNS-SD discovers Registries, not peer-to-peer nodes.
The node remains on Fetching Initial State.
Open the node and check its endpoint and connection status. Use Retry if the page shows No NMOS Data found.
Ports and Bundles shows no sources or destinations.
Confirm that the node exposes senders or receivers through IS-04 and that its connection is enabled.
The sender and receiver do not appear together in Routing.
Check the Connections filter above both lists and confirm that the intended connections are selected.
The route fails.
Open the route details and check the sender, receiver, compatibility, and IS-05 connection state before retrying.

Where to go next#

  • Understand NMOS in Buttons, for the concepts behind discovery and adoption.
  • Set up the built-in NMOS Registry Server.
  • Connect Buttons to an NMOS Registry.

Was this helpful?

Was this helpful?

0 of 0 users found this page helpful