Bitfocus AS
logo
logo
Bitfocus AS
logo
logo
Sign upSign in

Loading...

Bitfocus

Subscribe to our newsletter

The latest news, articles, and resources, sent to your inbox.

FacebookInstagramGitHubYouTubeLinkedIn

Products

  • Buttons
  • Companion

Integrations

  • Supported Devices
  • Developer Community
  • Connection Development

Support

  • Support Overview
  • Documentation
  • Video Tutorials
  • Community Forum

Sales

  • Resellers & Integrators
  • Buttons Pricing

Updates

  • Case Studies
  • Events & Trade Shows
  • Press Releases
  • Product Updates
  • Webinars

Legal

  • Legal Overview
  • Privacy Policy
  • Buttons EULA
  • Terms & Cookie Policy

Company

  • About us
  • Press kit
  • Careers

© 2026 Bitfocus AS. All rights reserved.

Connect Buttons to an NMOS Registry
Docs for
Overview
Getting started
What is Bitfocus Buttons?
Install Buttons and get started
Manage your Buttons license
Activate Buttons offline
Find your way around Buttons
Create your first backup
Add an ATEM connection
Choose a control method
Choose an installation path
Install Buttons on Debian or Ubuntu
Understand HA clustering
Kubernetes HA
Update or remove Buttons
Positions
Understand positions
Create a position
Add controls and sections to a position
Create your first button
Use a connection's presets
Build more capable button actions
Add more feedback to a button
Organize controls in a section
Shift Section
Organize controls with a Folder Section
Add a Popover Section
Build and reuse a Shared Section
Build a Router Section
Understand Custom Routers
Custom Router panel
Surfaces
Surface compatibility
Add and attach a surface
Device orientation
Connections
Update a connection's module safely
Monitor and troubleshoot a connection
Router integrations
VideoHub and AJA KUMO
Utah Scientific BPS
Generic SW-P-08
Nevion VideoIPath
Arkona BLADE//runner
Routing
Physical routing
Configure ports and labels
Take a physical route
Understand route status
Topology graph
Routing Presets
Get started with virtual routing
Configure Nested Shapes
Reverse routing
Tielines
Routing Projects
Routing settings
Troubleshoot a route
Tally
Understand the Tally system
Send ATEM tally and labels to a UMD
Interpret Active Tally state
TSL/UMD connections
Diagnose tally problems
NMOS
Understand NMOS in Buttons
Connect Buttons to an NMOS Registry
Built-in Registry Server
Configure NMOS connections
Discover and adopt
Browse the NMOS inventory
Manage NMOS multicast addresses
Diagnose NMOS problems
Understand Cuelists
Build a Cuelist
Read and advance a running Cuelist
Control a Cuelist from a Position
Workflows
Understand workflows
Build your first workflow
Reuse a group of workflow nodes safely
Troubleshoot a workflow
Recipes
Sequence a timed automation
Call an HTTP endpoint from a workflow
REST endpoint
Use variables
Understand variable scope
Understand nested variables
Update expressions for v1.8
Plan and use Tags
Access
Create and manage users
Create roles and assign permissions
Grant access to specific resources
Show different controls by role
Sessions
Set up PIN and NFC sign-in
SSO
Get started with SSO
Connect a generic OIDC provider
Connect LDAP or Active Directory
Map identity claims to roles
Secure a Buttons deployment
Integrations
External control
Connect to Bitfocus Listener
USB Relay
Install USB Relay on Windows
Install USB Relay on macOS
Install USB Relay on Linux
Install USB Relay on a Raspberry Pi
Get started with the Control API
Secure and monitor the Control API
Control API reference
API reference
Administration
Enable and manage installable features
Services and health
Configure and monitor scheduled backups
Restore a backup and verify it
Export or import Buttons configuration
Store and rotate connection secrets
Replace the HTTPS certificate
HA backup and recovery
Settings
Collect support information
Reference
Glossary
Button Inspector reference
Network ports reference
Expressions
Internal actions reference
Routing Presets panel reference
Startup configuration reference
Workflow nodes
Connection workflow nodes
Workflow workflow nodes
Internal workflow nodes
Position workflow nodes
API workflow nodes
Utility workflow nodes

Loading...

Previous
← Understand NMOS in Buttons
Next
Built-in Registry Server →
Contact support →
You are viewing documentation for Buttons 1.8.See the docs for Buttons 1.6
Buttons/NMOS/Connect Buttons to an NMOS Registry

Connect Buttons to an NMOS Registry

Connecting to a Registry lets Buttons see every node that registry already knows about in one place, then adopt only the ones you actually want to control: instead of waiting for each node to announce itself directly or adding them one at a time.
This is the right approach when nodes are already registering into a registry (Buttons' own built-in one, or a separate registry appliance) and you want deliberate control over which of its nodes become Buttons connections.

Before you begin#

You need:
  • The NMOS feature enabled (on by default).
  • Access to create NMOS connections.
  • The registry's reachable address, unless you're relying on discovery to find it.

Create the Registry connection#

  1. Open Connection → NMOS.
  2. Select Manual Add.
  3. Select Registry.
  4. Enter a Label.
  5. Leave IS-04 set to Auto unless the registry requires a specific supported version.
  6. Add one or more Registry endpoints. The lowest priority value is tried first; if it's unreachable, the next endpoint is used.
  7. Select Create.
Buttons confirms with Created NMOS Registry Connection! and adds the connection to the NMOS connection list.

Confirm the registry is reachable#

Open the new connection and its Registry tab. Registry reachability shows a live status dot, and each configured endpoint shows its own probe result: Reachable, Unreachable, or Probing registry endpoint... while a check is in progress.
Two further settings on this tab shape how the connection stays matched to the right registry:
  • Connection Mode: UUID follows a matching discovered registry automatically; Static endpoints uses only the endpoints you entered, ignoring discovery.
  • Registry UUIDs from Discovery Records: an allow-list of specific registry UUIDs this connection should follow, useful when more than one registry advertises on the network and you need to pin this connection to a particular one.

Choose what happens to nodes automatically#

Still on the Registry tab:
  • Node adoption: Manual leaves every node for you to adopt individually on the All Nodes tab; Adopt All adopts every node the registry reports automatically.
  • When a Node disappears: choose Do Nothing, Disable Node Connection, or Delete Node Connection for what happens to a connection that was created automatically for a node the registry no longer reports.

Browse and adopt nodes#

  1. Open the All Nodes tab.
  2. Review each node's API column to confirm its IS-04 version.
  3. Select Adopt on a single row, or select several rows and choose the batch Adopt action.
A successful adoption shows Node adopted!, and the node's status changes to Adopted. Adopted nodes also appear on the Adopted Nodes tab and in the main NMOS connection list, where you can open each one's own Node, Ports and Bundles, and Behaviors tabs the same way as a peer-to-peer node.

Set connection-scoped behaviors#

The Behaviors tab on a Registry connection uses the same behavior settings described in Configure NMOS connections, scoped to this registry connection instead of the whole system. Leave Inherit behaviors on to keep following the system-wide configuration, or turn it off to set different behaviors for every node this registry connection adopts.

If you get stuck#

What you see
What to try
The connection can't reach any endpoint.
Confirm the registry's address and port, and that Buttons' network can reach it. Check whether the registry itself is running.
A node the registry reports never becomes adoptable.
Confirm Node adoption isn't set in a way that excludes it, and that the node's own registration is current.
An adopted node's connection was unexpectedly disabled or deleted.
Check When a Node disappears: a node the registry stopped reporting is affected by whichever behavior is configured here.
Two registries keep competing for the same connection.
Use Registry UUIDs from Discovery Records to pin this connection to the intended registry, or switch Connection Mode to Static endpoints.

Where to go next#

  • Configure NMOS connections, for endpoint and IS-05 behavior settings, and to verify a route.
  • Diagnose NMOS problems, for registry and endpoint failures.

Was this helpful?

Was this helpful?

0 of 0 users found this page helpful